edefense shake table test

E-Defense Shake Table tests for Four-Story Post-Tensioned ...

E-Defense Shake Table tests for Four-Story Post-Tensioned Concrete Building 1. Background After the 1995 Hyogoken-Nanbu earthquake, buildings that suffered severe damages caused a social issue because of their expensive repair costs. The basic idea of earthquake disaster prevention concerned with

Full scale shake table testing of a two story mass timber ...

The two-story building shake table test conducted in 2017 is one of the investigative tests planned to validate the performance of the proposed mass timber building system with CLT rocking walls. To date, full-scale shake table test of a mass timber building with …

Collapse Assessment of Steel Moment Frames Based on E ...

This paper presents key parameters that affect numerical modeling of steel frame structures for reliable collapse simulations. The collapse assessment is based on experimental data obtained from a full-scale shaking table collapse test of a 4-story steel moment frame and a blind numerical analysis contest that was organized in parallel with the collapse test.

Pile group response to liquefaction-induced lateral ...

This paper presents the results of a large-scale shake table test at E-Defense facility on a pile group located adjacent to a gravity-type quay wall and were subjected to liquefaction-induced large ground displacements. Extensive liquefaction-induced large ground lateral spreading displaced the quay wall about 2.2 m and damaged the pile foundation.

Shake table testing of a full-scale seven-story steel–wood ...

This paper presents a summary of the results of two shake table tests on a full-scale seven-story mixed-use building. The test program took place during the summer of 2009 in Miki, Japan. The building consisted of a steel SMF at level 1, and light-frame wood for levels 2 through 7.

Collapse Assessment of Steel Moment Frames Based on E ...

Request PDF on ResearchGate | Collapse Assessment of Steel Moment Frames Based on E-Defense Full-Scale Shake Table Collapse Tests | Full scale shaking table tests of …

Numerical Modeling of Pile Group Response subjected to ...

a largescale shake table test conducted at - the E-Defense shake table facility in Japan. The main objective of this numerical simulation s to i evaluate the application and accuracy of 2D effective stress analyses in predicting soil-pile response subjected to liquefaction and lateral

Earthquake shaking table - Wikipedia

There are several different experimental techniques that can be used to test the response of structures and soil or rock slopes to verify their seismic performance, one of which is the use of an earthquake shaking table (a shaking table, or simply shake table).This is a device for shaking scaled slopes, structural models or building components with a wide range of simulated ground motions ...

Giorgio Proestos - Google Scholar Citations

Seismic assessment of the full scale four storey E-Defense rocking shear wall Shake Table Test. PM Proestos, Giorgio T., Aghabeigi, Hossein, Calvi. COMPDYN 2015 - 5th ECCOMAS Thematic Conference on Computational Methods in ...

ADVANCES IN SHAKE TABLE CONTROL AND …

Shake table tests provide a true representation of seismic phenomena including a fully dynamic environment with base excitation of the test structure. For this rea-son shake tables have become a staple in many earthquake engineering laboratories. While shake tables are widely used for research and commercial applications, further

SEISMIC PERFORMANCE AND REINFORCEMENT OF JAPANESE …

240 410 SEISMIC PERFORMANCE AND REINFORCEMENT OF JAPANESE HIGH-RISE BUILDINGS FACING SUBDUCTION EARTHQUAKE: E-DEFENSE SHAKE TABLE TESTS Takuya Nagae1, Masayoshi Nakashima2 1 National Research Institute for Earth Science and Disaster Prevention, Japan 2 Kyoto University, Japan Keywords: Subduction earthquake, high-rise building, large-scale test. ...

Shake Table | Seismic Testing | OSHPD Certification ...

DCL is a single source, state of the art lab for all required seismic, wind, and vibration simulation testing, analysis, reporting, and certification of equipment and systems. Our objective is to streamline the process for manufacturers to obtain code compliance through required shake table testing to …

Ceiling Anchorage Loads during Shake Table Tests of a Full ...

The test results show that the ceiling-to-slab ... "E-Defense," houses the world's largest shake table. ... CEILING ANCHORAGE LOADS DURING SHAKE TABLE TESTS OF A FULL-SCALE FIVE-STORY BUILDING 1453. The results presented in this paper focus on the ceiling response to the earthquake

NEES/E-Defense Base-Isolation Tests: Interaction of ...

A large-scale, shake-table test program was conducted with a goal of promoting rapid spread of base isolation systems in Japan and the U.S. In this program, a full-scale, five-story, steel moment-frame ... using the world's largest shake table, E-Defense. The building was tested under three different

The World's Largest Earthquake Simulator: Japan's E-Defense

Aug 21, 2015· The result is the E-Defense ("E" stands for Earth) shake table, measuring 20 by 15 meters, the world's largest earthquake simulator, located about 30km north of Kobe. The simulator is a basically a kinetic platform with 24 pneumatic pistons attached to the underside, controlled by a massive hydraulic mechanism.

E-Defense

02/10/2007 Finished live webcast of full-scale shaking table test 20/09/2007 Live webcast of full-scale shaking table test 03/08/2007 Deadline for registration of 2007 Blind Analysis was postponed till Aug. 15. 28/05/2007 Blind Analysis Registration starts

SEISMIC PERFORMANCE AND REINFORCEMENT OF …

240 410 SEISMIC PERFORMANCE AND REINFORCEMENT OF JAPANESE HIGH-RISE BUILDINGS FACING SUBDUCTION EARTHQUAKE: E-DEFENSE SHAKE TABLE TESTS Takuya Nagae1, Masayoshi Nakashima2 1 National Research Institute for Earth Science and Disaster Prevention, Japan 2 Kyoto University, Japan Keywords: Subduction earthquake, high-rise building, large-scale test. ...

E-Defense Shaking Table Test on the Behavior of ...

a shaking table test of largea -scale model with liquefiable sand deposit was performed at the E-Defense shaking table testing facility. The model in a rigid container 16 meters long, 4 meters wide and 5 meters high had a pile-foundation structure behind caissontype - quay wall in the deposit.

Shaking Table Test on Conventional Wooden House (1)

Nov 17, 2007· Shaking Table Test on Conventional Wooden House (1) neesit. Loading... Unsubscribe from neesit? ... They were actually built in Akashi city in Hyogo Pref. and moved to E-Defense. One of the houses ...

E-DEFENSE, JAPAN - WORLD'S LARGEST SHAKING TABLE

E-Defense (Earth-Defense) is the world's largest full-scale Earthquake (EQ) Shaking Table (ST) Facility which was established in 2005 at Hyogo Earthquake Engineering Research Center. It operates under the management of National Research Institute for Earth ... Ÿ 300 m2 (20 m X 15 m) Test Platform.

(PDF) Investigation of the Seismic Safety Capacity of Aged ...

PDF | In order to investigate the seismic safety capacity of the piping system with local wall thinning, shake table tests on 3-D piping system models were conducted using E-Defense. Two piping ...

Feature Stories - University of Texas at Austin

Jan 30, 2014· Feature Stories Full-Scale Building Tests on World's Largest Earthquake Shaking Table. Located just north of Kobe in Miki City, Japan, the E-Defense shake table measures approximately 65 by 49 ft. and can support building experiments weighing over two million pounds.

Collaboration on NEES Testing | Simpson Strong-Tie

The condo building was subjected to Japan's E-Defense (Earth-Defense) shake table, which simulates the ground motions of an earthquake. Located just north of Kobe in Miki City, Japan, the E-Defense shake table measures approximately 65 by 49 ft. and can support building experiments weighing up to 2.5 million pounds.

Shake table test procedure - Henan Mining Machinery Co., Ltd.

200987conduct shake table test using EDefense on two type models; 1 ponent models and 2 system models They are called C1 test C1 models and C2 test C2 models, respectively Component experiments single columns Component experiments on single RC column models with as large sections as possible was proposed as shown. Email:[email protected]

E-Defense 6 Story Shake Table part 1 - YouTube

May 04, 2007· Video of the 6 story shake table test in Japan. Video of the 6 story shake table test in Japan. ... E-Defense 6 Story Shake Table part 2 - Duration: 6:01. neesit 20,963 views.

Investigation of the Seismic Safety Capacity of Aged ...

In order to investigate the seismic safety capacity of the piping system with local wall thinning, shake table tests on 3-D piping system models were conducted using E-Defense. Two piping system models which were the same in appearance and different in degradation condition were arranged on the shake table of E-Defense.

Shake-Table Test of a Full-Scale 4-Story Precast Concrete ...

In 2010, a full-scale, 4-story precast concrete building was tested on the E-Defense shake table. The lateral-force-resisting system of the building included unbonded posttensioned (UPT) concrete walls in one direction and bonded posttensioned frames in the orthogonal direction.

E-Defense shake table test on retrofitted high-rise ...

In this research, quake resistance of a high-rise building is verified through the shake table experiments conducted by E-Defense. The most likely height of high-rise buildings is considered to be about 80 m in Japan. The test specimen is designed to represent seismic responses of a 80 m tall steel building.

Shaking table tests on RC frame building with unreinforced ...

Mar 22, 2014· Shaking table tests on RC frame building with unreinforced infill walls ... Seismic Test for 30 Storey BSB Factory Built Building in Beijing Earth Quake ... E-Defense 6 Story Shake Table part 1 ...